Quiet, powerful, Generac OHVI V-Twin engine
fueled by natural gas or LP.
-
UL Listed remote-mounted pre-wired automatic
transfer switch with 10 or 12 circuit emergency load center
for fast and efficient unattended transfer to generator when
utility power fails.
-
A standard weather protective enclosure with
sound-absorbing panels protects generator from harmful
weather and also reduces exterior noise levels. Includes key
locks for security.
-
Hinged top and removable front panel for
easy serviceability.
-
Built-in charger maintains battery at
optimum performance level.
-
Automatic safety shutdowns protect engine
and generator in event of low oil pressure, high
temperature, overspeed and/or overcrank.
-
Automatic seven day exerciser runs the
system for twelve minutes weekly to maintain top running
condition.
-
Installation kit includes a pre-wired
automatic transfer switch with built-in load center, 30' and
2' wiring harnesses, pre-wired external connection box, 1'
flexible fuel line, "Do-It-Yourself" installation
guide and a composite mounting pad.
|
GENERATOR SET
|
|
Model
Number
|
04456
|
04390
|
|
Rated
Power LP (kW)*
|
12
|
15**
|
|
Rated
Power NG (kW)*
|
10
|
13
|
|
Voltage
@ 60 Hz
|
120/240
|
120/240
|
|
Phase
|
Single
|
Single
|
|
Frequency
|
60
Hz
|
60
Hz
|
|
Amps
(NG)
|
83.3/41.6
|
108.3/54.2
|
|
Engine/Alternator
RPM
|
3600/3600
|
3600/3600
|
|
Engine
|
760
cc.
26 HP
Generac OHVI
V-Twin
|
992
cc.
30 HP
Generac OHVI
V-Twin
|
|
EPA/CARB
Certified
|
Yes
|
Yes
|
|
Fuel
|
Natural
Gas/
LP Vapor
|
Natural
Gas/
LP Vapor
|
|
Engine
Cooling
|
Air
|
Air
|
|
CSA
Listed
|
Yes
|
Yes
|
|
UL
2200 Listed
|
Yes
|
Yes
|
|
Main
Line Circuit Breaker
|
50
Amp
|
60
Amp
|
|
Dimensions
(L" x W" x H")
|
48
x 24 x 28-1/4
|
48
x 24 x 28-1/4
|
|
Shipping
Wt. (lbs.)
|
470
|
487
|
|
*
Natural gas and LP gas ratings may decrease depending on
BTU content of local gas supply. Proper sizing of
tank/piping is required to ensure full output.
** As equipped, generator will produce 13,000 watts. If
you intend to run LP configuration at 15,000 watts,
please contact Generac for required kit.
|
| CONTROLS |
| Start/Stop
Control |
Cyclic
cranking: 7 seconds on, 7 seconds rest. 90 seconds
overcrank protection. |
| Automatic Low
Oil Shutdown |
Standard |
| Overspeed
Shutdown |
Standard,
72 Hz |
| Overcrank
Protection |
Standard |
| Automatic
Voltage Regulator with Over-Voltage Protection |
Standard |
| Engine Warmup |
10
seconds |
| Engine Cool-Down |
1
minute |
| Safety Fuse |
Standard |
| Starter Lockout |
Starter
cannot re-engage until 5 seconds after the engine has
stopped |
| 2 Amp Timed
Trickle Battery Charger |
Standard |
Mode
Switch
* Auto switch
* Off switch
* Manual / test
|
Utility failure/7 day exercise
Stops unit. Power is removed.
Control and charger still operate
Start with starter control,
unit stays on. If utility fails,
transfer to load takes place
|
| TRANSFER SWITCH |
| No. of Poles |
2 |
| Current Rating
(amps) |
100 |
| Voltage Rating (VAC) |
250 |
| Utility
Voltage Monitor (fixed)
|
| Return to
Utility |
Approx.
13 seconds |
| Exercises 7
minutes weekly |
Standard |
| UL Listed |
Standard |
| Dimensions
(H" x W" x D") |
26.5
x 12.5 x 7 |
|
|